A sodar system requires a minimum of three non-coplanar beams to get three independent measures of the atmospheric wind flow (represented by a 3D vector). Unavoidably, these three beams will divert with increasing height. To compute a representative common wind vector from the three independent measurements a horizontally homogenous wind flow is assumed. This is fulfilled in most atmospheric conditions for time intervals of 10 … 30 min. However, under strong convective conditions this basic assumption is still not fulfilled. The consequence is an increase of the statistical error in the computed 3D wind vector (i.e. the derived wind vector will fluctuate in direction and length).