Quick answers to technical questions may be found in our FAQ list. It is structured according to the following product groups: Doppler SODAR PCS.2000 (SDR), Sonic Anemometer uSonic (SNC), Micro Rain RADAR (MRR), Temperature Profiler (RASS), Doppler Cloud RADAR (MIRA), Doppler LIDAR Wind Ranger (LDR-WR) and Doppler Wind LIDAR Streamline (LDR-SL).
Pleas note that this site is still in progress. If your product or question does not show up in our list, please use the contact field below and we will come back to you shortly.
The multi frequency mode allows a consecutive transmission of several frequencies within one acoustic pulse sequence. Because the atmospheric attenuation decreases for lower frequencies, the multi frequency pulse starts with a low frequency followed by increasing frequencies. This allows to use low frequencies for signals backscattered from upper heights while the highest frequencies are used for the lowest measuring heights. The separation of selected frequencies should be of the order of 250 Hz to avoid ambiguities in the received signal, so the number of selected frequencies should be limited to 4 to 5. Example: 1300 Hz, 1550 Hz, 1800 Hz, 2050 Hz, 2400 Hz.