Quick answers to technical questions may be found in our FAQ list. It is structured according to the following product groups: Doppler SODAR PCS.2000 (SDR), Sonic Anemometer uSonic (SNC), Micro Rain RADAR (MRR), Temperature Profiler (RASS), Doppler Cloud RADAR (MIRA), Doppler LIDAR Wind Ranger (LDR-WR) and Doppler Wind LIDAR Streamline (LDR-SL).
Pleas note that this site is still in progress. If your product or question does not show up in our list, please use the contact field below and we will come back to you shortly.
All RADAR signals experience a certain attenuation as the cable length increases. This is of secondary importance for transmission operation because an amplified signal is used here. On the receiving side, however, there is only a low signal level as the amplification does not take place directly in the RADAR receiving antenna. Attenuation on the way to the receiving amplifier must therefore be minimised. The RADAR receiver should therefore be positioned close to the RADAR receiving antenna. If this is not possible, special signal cables with particularly low attenuation coefficients can be used. These are not flexible and are only suitable for fixed installation due to their design.